ELECTROLUX-REX KTI6500BE Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
min.
12 mm
min.
2 mm
8.5 Protection box
If you use a protection box (an additional
accessory), the front airflow space of 2
mm and the protective floor directly below
the hob are not necessary. The protection
box accessory may not be available in
some countries. Please contact your local
supplier.
You can not use the
protection box if you install
the hob above an oven.
9. TECHNICAL INFORMATION
9.1 Cooking zones specification
Cooking zone Nominal pow-
er (maximum
heat setting)
[W]
Power func-
tion [W]
Power func-
tion maximum
duration [min]
Cookware di-
ameter [mm]
Left front 2300 3200 10 125 - 210
Left rear 2300 3200 10 125 - 210
Right front 1400 2500 4 125 - 145
Right rear 1800 2800 10 145 - 180
The power of the cooking zones can be
different in some small range from the
data in the table. It changes with the
material and dimensions of the cookware.
For optimal cooking results use cookware
not larger than the diameter in the table.
www.electrolux.com18
Vue de la page 17